Designing of ultraviolet irradiation unit: Effects on disinfection performance and operating costs

Abstract

The effect of the design of ultraviolet irradiation unit on disinfection performance and operating costs was investigated for aquaculture purposes. Two prototypes (H and U) were compared with a commercial UV filter (I). The water samples for microbiological cultivation were obtained from water inlet and outlet of three different types of UV units in four replicates at 15°C and 25°C of sea water temperatures. Finally, considering the efficiency of reduction the total heterotrophic bacterial load of the UV filters, although significant differences were not found statistically, the best results were obtained from U type UV chamber at both temperatures (15°C and 25°C) (P>0.05).. Also, it was estimated that make 60% savings in renewal and operating costs can be possible with changing the design of UV chamber.

Keywords

Kaynakça

  1. Barnes, M.E. & Brown, M.L. (2011). A review of Flavobacterium psychrophilum biology, clinical signs, and bacterial cold water disease prevention and treatment. The Open Fish Science Journal, 4, 40–48. DOI: 10.2174/1874401X01104010040
  2. Gebauer, R., Eggen, G., Hansen, E. & Eikebrokk, B. (1992). Oppdrettsteknologi: vannkvalitet og vannbehandling i lukkede oppdrettsanlegg. Tapir Forlag [in Norwegian].
  3. Gómez, M., Plaza, F., Garralón, G., Pérez, J. & Gómez, M.A. (2007). A comparative study of tertiary wastewater treatment by physico-chemical-UV process and macrofiltration–ultrafiltration technologies. Desalination, 202, 369-376. DOI:10.1016/j.desal.2005.12.076
  4. Lazarova, V., Davoye, P., Janex, M.L., Blatchley, E.R. & Pommepuy, M. (1999). Advanced wastewater disinfection technologies: state of the art and perspectives. Water Science Technology, 40(4-5), 203-213. DOI:10.1016/S0273-1223(99)00502-8
  5. Leonard N., Blancheton J.P., & Guiraud J.P. (2000). Populations of heterotrophic bacteria in an experimental recirculating aquaculture system. Aquacultural Engineering;22(1-2),109–120. DOI 10.1016/s0144-8609(00)00035-2
  6. Lekang, O. I. (2013). Aquaculture Engineering (Second Edition). John Wiley & Sons, Ltd., UK
  7. Liltved, H., Hektoen, H. & Efrainsen, H. (1995). Inactivation of bacterial and viral fish pathogens by ozonation or UV radiation in water of different salinity. Aquacultural Engineering, 14(2), 107–122. DOI:10.1016/0144-8609(94)P4430-J
  8. Patterson, R.N., Watts, K.C. & Timmons, M.B. (1999). The power law in particle size analysis for aquacultural facilities. Aquacultural Engineering, 19(4), 259-273.DOI: 10.1016/S0144-8609(98)00054-5

Ayrıntılar

Birincil Dil

İngilizce

Konular

-

Bölüm

Araştırma Makalesi

Yayımlanma Tarihi

15 Haziran 2018

Gönderilme Tarihi

29 Ocak 2018

Kabul Tarihi

7 Mart 2018

Yayımlandığı Sayı

Yıl 1970 Cilt: 35 Sayı: 2

Kaynak Göster

APA
Şen, H., & Karacalar, U. (2018). Designing of ultraviolet irradiation unit: Effects on disinfection performance and operating costs. Ege Journal of Fisheries and Aquatic Sciences, 35(2), 121-124. https://doi.org/10.12714/egejfas.2018.35.2.03